Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference page 58

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

1
Reading a RAS System Message
The fields in the error message are described in table below.
TABLE 4
Example
AUDIT
2005/12/10-09:54:03
[SEC-1000]
WARNING
SECURITY
JohnSmith
root
192.168.132.10
Telnet
CLI
Domain A
switchname
, ,
Slot 7 ejector not
closed
10
AUDIT, 2005/12/10-09:54:03, [SEC-1000], WARNING, SECURITY,
JohnSmith/root/192.168.132.10/Telnet/CLI, Domain A/JohnsSwitch, , Incorrect
password during login attempt.
Audit Message Field Description
Variable Name
Audit flag
Date and Time Stamp
Message Module and
Message Number
Severity Level
Event Class
User ID
Role
IP Address
Interface
Application Name
Admin Domain
Switch name or chassis
name, depending on
the action; for example,
HA messages typically
show the chassis name
and login failures show
the logical switch
name.
Null
Error Description
Description
Identifies the message as an Audit message.
The system time (UTC) when the message was
generated on the switch. The RASLog subsystem will
support an internationalized timestamp format base
on the "LOCAL" setting.
Displays the message module and number. These
values uniquely identify each message in the Fabric OS
and reference the cause and actions recommended in
this manual. Note that not all message numbers are
used; there can be gaps in the numeric message
sequence.
Displays the severity of the error in alpha format:
1 = Critical
2 = Error
3 = Warning
4 = Info
Identifies the event class as one of the following:
Zone
Security
Configuration
Firmware
Fabric
Identifies the user ID.
Identifies the role of the user ID.
Identifies the IP address.
Identifies the interface being used.
Identifies the application name being used on the
interface.
Identifies the Admin Domain, if there is one.
This field displays the defined switch name or the
chassis name of the switch. This value is truncated if it
is over 16 characters in length. Run either the
chassisName command to name the chassis or the
switchName command to rename the logical switch.
Reserved for future use.
This field displays a text string explaining the
error encountered and providing parameters
supplied by the software at runtime.
Fabric OS Message Reference
53-1000437-01

Advertisement

Table of Contents
loading

Table of Contents