MS-1009

MS-1009
Message
<timestamp>, [MS-1009], <sequence-number>,, ERROR, <system-name>, RLIR event.
Switch Port ID is <PID>. Device Port Tag is <port tag>. <message>.
Probable Cause
A Registered Link Incident Record (RLIR) has been generated for one of the actions clarified by the
<message> passed in.
The following messages might be displayed:
Recommended
Persistent RLIR incidents are likely due to SAN hardware problems such as bad cables, small
Action
form-factor pluggables (SFPs), etc. It may be necessary to replace hardware if these messages
persist.
Severity
ERROR

MS-1021

Message
<timestamp>, [MS-1021], <sequence-number>,, ERROR, <system-name>, MS WARMBOOT
failure(FSS_MS_WARMINIT failed. Reason=
Probable Cause
Indicates that the Fabric OS state synchronization (FSS) warm recovery failed during WARM INIT
phase of a reboot.
Recommended
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
Action
supportSave command and contact your switch service provider.
Severity
ERROR

MS-1022

Message
<timestamp>, [MS-1022], <sequence-number>,, INFO, <system-name>, Management
Server Platform Service
Probable Cause
Indicates that Management Server Platform Service is being activated or deactivated.
Recommended
No action is required.
Action
Severity
INFO
296
Exceeded bit error rate threshold
Loss of signal or synchronization
Not operational seq. recognized
Primitive sequence timeout
Unrecognized link incident
<Activated or Deactivated>
<failure reason>
)
Fabric OS Message Reference
53-1000437-01