Hil-1101; Hil-1102; Hil-1103; Hil System Messages - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

HIL System Messages

HIL-1101

Message
<timestamp>, [HIL-1101], <sequence-number>,, ERROR, <system-name>, Slot <slot
number> faulted, <nominal voltage> (<measured voltage>) is above threshold.
Probable Cause
Indicates that the blade voltage is above the threshold.
Recommended
Replace the faulty blade or switch (for nonbladed switches).
Action
Severity
ERROR

HIL-1102

Message
<timestamp>, [HIL-1102], <sequence-number>,, ERROR, <system-name>, Slot <slot
number> faulted, <nominal voltage> (<measured voltage>) is below threshold.
Probable Cause
Indicates that the blade voltage is below the threshold.
Recommended
Replace the faulty blade or switch (for nonbladed switches).
Action
Severity
ERROR

HIL-1103

Message
<timestamp>, [HIL-1103], <sequence-number>,, ERROR, <system-name>, Blower <blower
number> faulted, <nominal voltage> (<measured voltage>) is above threshold.
Probable Cause
Indicates that the fan voltage is above threshold.
Recommended
Run the psShow command to verify the power supply status.
Action
Try to reseat the faulty fan field-replaceable unit (FRU) and power supply FRU to verify that they are
seated properly.
If the problem persists, replace the fan FRU or the power supply FRU as necessary.
Severity
ERROR
Fabric OS Message Reference
53-1000437-01
Chapter
30
241

Advertisement

Table of Contents
loading

Table of Contents