Fw-1050; Fw-1051; Fw-1052 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

FW-1050

Message
<timestamp>, [FW-1050], <sequence-number>,, WARNING, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has fallen below the low
boundary.
Recommended
Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0
Action
(Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates.
Severity
WARNING

FW-1051

Message
<timestamp>, [FW-1051], <sequence-number>,, WARNING, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high
boundary. High voltages indicate possible hardware failures. Frequent voltage fluctuations are an
indication that the SFP is deteriorating.
Recommended
If you see frequent voltage fluctuations, replace the SFP.
Action
Severity
WARNING

FW-1052

Message
<timestamp>, [FW-1052], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the
Action
end-user installation.
Severity
INFO