HIL-1206

Message
<timestamp>, [HIL-1206], <sequence-number>,, ERROR, <system-name>, Fan <fan
number> sensor <sensor number> , speed (<measured speed> RPM) below threshold.
Probable Cause
Indicates that the specified fan speed (in RPM) has fallen below the minimum threshold. This
problem can quickly cause the switch to overheat. This message is specific to nonbladed switches
and is not applicable to the Brocade 24000, or 48000.
Recommended
For the Brocade 4100, 4900, 7500, and AP7600, replace the fan field-replaceable unit (FRU).
Action
Severity
ERROR

HIL-1207

Message
<timestamp>, [HIL-1207], <sequence-number>,, ERROR, <system-name>, Fan
number>
Probable Cause
Indicates that the fan is faulty.
Recommended
Use the tempShow command to verify that the switch temperatures are within operational range.
Action
Refer to the hardware reference manual for the temperature range of your switch.
Make sure that the area is well ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Use the fanShow command to monitor the status of the fan generating this error.
If the fan continues to generate this message, replace the switch because the fan is not
field-replaceable.
Severity
ERROR

HIL-1208

Message
<timestamp>, [HIL-1208], <sequence-number>,, INFO, <system-name>, Fan
number>
Probable Cause
Indicates that the fan is not faulty.
Recommended
This can only occur on switches with non-removable fans. It follows a previous indication of
Action
faultiness.
If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty
behavior. Replace the switch because the fan is not field-replaceable.
Severity
INFO
Fabric OS Message Reference
53-1000437-01
is faulty.
is not faulty.