Sulb-1009 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

SULB-1009

Message
AUDIT, <timestamp>, [SULB-1009], AUDIT, INFO, FIRMWARE,
<event-initiator-details>, <event-location>, , Firmwaredownload command failed.
status: 0x<status code>, error: 0x<error code>.
Probable Cause
Indicates that the firmwareDownload command failed. The additional status code and error code
provide debugging information.
Table
in this RASLOG message. They are listed for the sake of completeness.
TABLE 6
Status Message
"firmwareDownload sanity check failed."
"Sanity check failed because system is non-redundant."
"Sanity check failed because firmwareDownload is already in progress."
"Sanity check failed because FABRIC OS is disabled on Active CP."
"Sanity check failed because HAMD is disabled on Active CP."
"Sanity check failed because firmwareDownload is already in progress."
"Sanity check failed because FABRIC OS is disabled on Standby CP."
"Sanity check failed because HAMD is disabled on Standby CP."
"firmwareDownload failed on Standby CP."
"firmwareDownload failed on Standby CP."
"firmwareDownload failed on Standby CP."
"firmwareCommit failed on Standby CP."
"firmwareDownload failed."
"firmwareDownload failed due to IPC error."
"Unable to check the firmware version on Standby CP due to IPC error."
"firmwareDownload failed due to IPC error."
"firmwareDownload failed due to IPC error."
"Standby CP failed to reboot due to IPC error."
"firmwareCommit operation failed due to IPC error."
"Unable to check the firmware version on Standby CP due to IPC error."
"Unable to restore the original firmware due to Standby CP timeout."
"Standby CP failed to reboot and was not responding."
"Unable to check the firmware version on Standby CP due to IPC error."
"Sanity check failed because firmwareDownload is already in progress."
"Sanity check failed because firmwareDownload is already in progress."
NOT USED
"System Error."
"Active CP forced failover succeeded. Now this CP becomes Active."
Fabric OS Message Reference
53-1000437-01
lists firmwareDownload status messages and status codes. Some of them will not show up
Status Messages and Status Codes
66
SULB-1009
Status Code
0x30
0x31
0x32
0x33
0x34
0x35
0x36
0x37
0x40
0x41
0x42
0x43
0x44
0x50
0x51
0x52
0x53
0x54
0x55
0x56
0x57
0x58
0x59
0x60
0x61
0x62
0x63
0x64
401