30

HIL-1309

Recommended
Replace the faulty fan field-replaceable units (FRUs) immediately.
Action
Severity
ERROR
HIL-1309
Message
<timestamp>, [HIL-1309], <sequence-number>,, ERROR, <system-name>,
FRUs failed. Replace failed fan FRUs immediately.
Probable Cause
Indicates that multiple fans have failed. This message is often preceded by a low fan speed
message.
Recommended
Replace the faulty fan field-replaceable unit (FRU)s immediately.
Action
Severity
ERROR

HIL-1310

Message
<timestamp>, [HIL-1310], <sequence-number>,, WARNING, <system-name>,
fan(s) faulty.
Probable Cause
Indicates that multiple fans have failed. This message is often preceded by a low fan speed
message.
Recommended
Since the fans are not field replaceable, replace the switch if the temperature is high.
Action
Severity
WARNING

HIL-1311

Message
<timestamp>, [HIL-1311], <sequence-number>,, INFO, <system-name>, No fans are
faulty.
Probable Cause
Indicates recovery from earlier condition of one or more fans having failed.
Recommended
This can only occur on switches with non-removable fans. It follows a previous indication of
Action
faultiness.
If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty
behavior. Replace the switch because the fan is not field-replaceable.
Severity
INFO

HIL-1401

Message
<timestamp>, [HIL-1401], <sequence-number>,, WARNING, <system-name>, One fan FRU
missing. Install fan FRU immediately.