Fcr-1030; Fcr-1031; Fcr-1032; Fcr-1033 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

To avoid WWN conflicts, all EX_Ports attached to fabrics with highly dynamic changes to EX_Port
connectivity should be disabled then reenabled.
Severity
INFO

FCR-1030

Message
<timestamp>, [FCR-1030], <sequence-number>,, INFO, <system-name>, Physical device
<device WWN> came online at fabric <fabric ID>.
Probable Cause
Indicates that the physical device world-wide name (WWN) came online in the specified fabric.
Recommended
No action is required.
Action
Severity
INFO

FCR-1031

Message
<timestamp>, [FCR-1031], <sequence-number>,, INFO, <system-name>, Physical device
<device WWN> went offline in fabric <fabric ID>.
Probable Cause
Indicates that the physical device world-wide name (WWN) went offline in the specified fabric.
Recommended
No action is required.
Action
Severity
INFO

FCR-1032

Message
<timestamp>, [FCR-1032], <sequence-number>,, INFO, <system-name>, Edge fabric
enabled security on port <port number> in fabric <fabric ID>.
Probable Cause
Indicates that Secure mode was turned on in the edge fabric.
Recommended
No action is required.
Action
Severity
INFO

FCR-1033

Message
<timestamp>, [FCR-1033], <sequence-number>,, INFO, <system-name>, Edge fabric
disabled security on port <port number> in fabric <fabric ID>.
Probable Cause
Indicates that Secure mode was turned off in the edge fabric.
Fabric OS Message Reference
53-1000437-01
20
FCR-1030
125

Advertisement

Table of Contents
loading

Table of Contents