Sulb-1020; Sulb-1021; Sulb-1022 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

66

SULB-1020

Probable Cause
The error may be caused by a blade initialization issue after the new firmware is downloaded and
the blade is rebooted. The error may also be caused by an internal Ethernet issue or by a persistent
storage failure.
Recommended
Run the slotShow command. If the blade is in FAULTY state, run the slotPowerOff and slotPowerOn
Action
commands to trigger another firmwareDownload. If the blade is stuck in LOADING state, remove
and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your
switch service provider.
Severity
ERROR
SULB-1020
Message
<timestamp>, [SULB-1020], AUDIT, ERROR, <system-name>, New firmware failed to boot
in slot
Probable Cause
The BP blade should reboot with the new image, but is still running the old image. This error may
indicate that the new image has not been loaded correctly to the specified blade.
Recommended
Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and
Action
slotPowerOn commands to trigger another firmwareDownload to the blade. If the blade is stuck in
LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the
problem persists, contact your switch service provider.
Severity
ERROR

SULB-1021

Message
<timestamp>, [SULB-1021],<sequence-number>, AUDIT, WARNING, <system-name>,
Firmware is being downloaded to the blade in slot
Probable Cause
Indicates that the firmware is being loaded to the indicated blade.
Recommended
Run the firmwareDownloadStatus command to monitor the firmwareDownload progress. After it
Action
finishes, run the firmwareShow command to verify the firmware versions.
Severity
WARNING

SULB-1022

Message
<timestamp>, [SULB-1022], <sequence-number>,, WARNING, <system-name>, The blade
in slot
Probable Cause
Indicates that the blade in the specified slot has rebooted with new firmware. This is a normal step
in the firmwareDownload process.
Recommended
Run the firmwareDownloadStatus command to monitor the firmwareDownload progress.
Action
408
<Slot number>.
<Slot number>
has rebooted successfully with new firmware.
<Slot number>
.
Fabric OS Message Reference
53-1000437-01