Fss-1001; Fss-1002; Fss System Messages - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

FSS System Messages

FSS-1001

Message
<timestamp>, [FSS-1001], <sequence-number>,, WARNING, <system-name>, Component
(<component name>) dropping HA data update (<update ID>).
Probable Cause
Indicates that an application has dropped a high availability (HA) data update.
Recommended
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
Action
system.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING

FSS-1002

Message
<timestamp>, [FSS-1002], <sequence-number>,, WARNING, <system-name>, Component
(<component name>) sending too many concurrent HA data update transactions
(<dropped update transaction ID>)
Probable Cause
Indicates that an application has sent too many concurrent high availability (HA) data updates.
Recommended
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
Action
system.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
Fabric OS Message Reference
53-1000437-01
Chapter
25
149