FW-1240

FW-1240
Message
<timestamp>, [FW-1240], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause
Indicates that the number of end-to-end (EE) cyclic redundancy check (CRC) errors has changed.
Invalid CRC messages occur when the number of CRC errors in Fibre Channel frames for specific
source ID (S_ID) and destination ID (D_ID) pairs change. These messages might also be caused by
dirty equipment, temperature fluctuations, and aging equipment.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the
Action
end-user installation.
Severity
INFO

FW-1241

Message
<timestamp>, [FW-1241], <sequence-number>,, INFO, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the number of end-to-end (EE) cyclic redundancy check (CRC) errors has fallen below
the low boundary. Invalid CRC messages occur when the number of CRC errors in Fibre Channel
frames for specific source ID (S_ID) and destination ID (D_ID) pairs change. These messages might
also be caused by dirty equipment, temperature fluctuations, and aging equipment.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the
Action
end-user installation. A low number of CRC errors means that the fabric is functioning normally.
The CRC error area of the End-to-End Performance Monitor class helps you tune your fabric. To
reduce CRC messages, experiment with alternative topologies and cabling schemes.
Severity
INFO

FW-1242

Message
<timestamp>, [FW-1242], <sequence-number>,, WARNING, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the number of end-to-end (EE) cyclic redundancy check (CRC) errors has risen above
the high boundary. Invalid CRC messages occur when the number of CRC errors in Fibre Channel
frames for specific source ID (S_ID) and destination ID (D_ID) pairs change. These messages might
also be caused by dirty equipment, temperature fluctuations, and aging equipment.
Recommended
The CRC error area of the end-to-end performance monitor class helps the user tune the fabric. To
Action
reduce CRC errors, experiment with alternative topologies and cabling schemes. Clean equipment,
check temperatures, and replace old hardware.
Severity
WARNING