Trce-1009; Trce-1010; Trce-1011 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

70

TRCE-1009

TRCE-1009
Message
<timestamp>, [TRCE-1009], <sequence-number>,, ERROR, <system-name>, Unable to
alert active CP that a dump has occurred.
Probable Cause
Indicates that the standby CP is unable to communicate trace information to active CP. This
message is only applicable to the Brocade 24000 and 48000.
Recommended
Run the haShow command to verify that the current CP is standby and the active CP is active.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR

TRCE-1010

Message
<timestamp>, [TRCE-1010], <sequence-number>,, ERROR, <system-name>, Traced fails
to start
Probable Cause
Indicates that the trace daemon (traced), used for transferring trace files, failed to start. The trace
capability within the switch is unaffected. The traced facility is normally restarted automatically by
the system after a brief delay.
Recommended
If the message persists, reboot the CP (dual-CP system) or restart the switch.
Action
Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity
ERROR

TRCE-1011

Message
<timestamp>, [TRCE-1011], <sequence-number>,, INFO, <system-name>, Trace dump
manually transferred to target ' <optional string to indicate which slot the dump
is ftped out.> ': <result>.
Probable Cause
Indicates that a manual transfer of trace dump files has occurred.
Recommended
No action is required.
Action
Severity
INFO
424
Fabric OS Message Reference
53-1000437-01