<timestamp>, [FSPF-1005], <sequence-number>,, ERROR, <system-name>, Wrong Section
Id <section number>, should be <section number>, input port = <port number>
Probable Cause
Indicates that an incorrect section ID was reported from the specified input port. The section ID is
used to identify a set of switches that share an identical topology database. The section ID is
implemented inside the protocol. The error message itself will indicate the mismatched section ID.
It should be set to 0 for a nonhierarchical fabric. Brocade switches support only section ID 0.
Recommended
Use a frame analyzer to verify that the reported section ID is 0. Any connected (other manufacturer)
Action
switch with a section ID other than 0 is incompatible in a fabric of Brocade switches. Disconnect
the offending switch.
Severity
ERROR

FSPF-1006

Message
<timestamp>, [FSPF-1006], <sequence-number>,, ERROR, <system-name>, FSPF Version
<FSFP version> not supported, input port = <port number>
Probable Cause
Indicates that the FSPF version is not supported on the specified input port.
Recommended
Update the FSPF version by running the firmwareDownload command to update the firmware to
Action
the latest version. All current versions of the Fabric OS support FSPF version 2, which is the correct
version.
Severity
ERROR