Fw-1444; Fw-1445; Fw-1446 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

FW-1444

Message
<timestamp>, [FW-1444], <sequence-number>,, WARNING, <system-name>, <FRU label>
state has changed to <FRU state>.
Probable Cause
Indicates that the state of the specified field-replaceable unit (FRU) has changed to "faulty".
Recommended
Replace the FRU.
Action
Severity
WARNING

FW-1445

Message
<timestamp>, [FW-1445], <sequence-number>,, INFO, <system-name>, Four power
supplies are now required for 2X redundancy, Switch Status Policy values changed.
Probable Cause
Indicates that the switch now requires 4 power supplies and previous Switch Status Policy
parameters will be overwritten to reflect this. The presence of an AP blade means that more than
one power supply may be required to provide adequate power. So (even if the AP blade is powered
down or removed) the Switch Status policy values will now reflect the need for 4 power supplies to
maintain full (2X) redundancy.
Recommended
No action required, unless there are fewer than 4 power supplies active in the chassis. If there are
Action
fewer than 4, insert additional power supplies so that there are 4 active.
Severity
INFO

FW-1446

Message
<timestamp>, [FW-1446], <sequence-number>,, WARNING, <system-name>, Four power
supplies now required for 2X redundancy, not enforced by Fabric Watch due to
Switch Status Policy overridden by User.
Probable Cause
Indicates that the switch now requires 4 power supplies for full (2X) redundancy, but the user has
previously overridden the Switch Status Policy values pertaining to number of power supplies. So
those values will not be automatically changed. The default values with no AP blades are: 3 out of
service indicates switch status is DOWN, 0 indicates no checking for switch status MARGINAL. The
default values when an AP blade is or has been present are: 2 out of service indicates switch
status is DOWN, 1 out of service indicates switch status is MARGINAL
Recommended
To maintain full (2X) redundancy and proper monitoring by Fabric Watch, 4 active power supplies
Action
should be supplied and the default values associated with the presence of an AP blade should be
entered with switchStatusPolicyset.
Severity
WARNING