Zone-1006; Zone-1007; Zone-1008 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

ZONE-1006

Message
<timestamp>, [ZONE-1006], <sequence-number>,, WARNING, <system-name>, WARNING -
WWN(<WWN number>) in HARD PORT zone <zone_name>.
Probable Cause
Indicates that one or more devices are zoned as world-wide name (WWN) devices and also zoned
as <domain, portarea> devices. The device(s) are used to specify zone members over separate
zones.
Recommended
If hardware zoning enforcement is preferred, edit the zoning database to have the device zoned
Action
using only one specification type, either WWN or <domain, portarea>.
Severity
WARNING

ZONE-1007

Message
<timestamp>, [ZONE-1007], <sequence-number>,, INFO, <system-name>,
Ioctl(<function>) in (<error message>) at port (<port number>) returns code
(<error string>) and reason string (<reason string>).
Probable Cause
Indicates that frame filter logic reported a failure during one of the IOCTL calls. The IOCTL call from
which the failure is reported is listed as part of the error message. This is usually a programming
error when adding content-addressable memory (CAM) entries before the filter setup.
Recommended
There are two ways to avoid this problem.
Action
Severity
INFO

ZONE-1008

Message
<timestamp>, [ZONE-1008], <sequence-number>,, WARNING, <system-name>, WARNING -
port
Probable Cause
Indicates that the total number of entries of S_ID CAM is above the limit while creating or adding a
zone group. The maximum number of content-addressable memory (CAM) entries allowed depends
on the application-specific integrated circuit (ASIC).
Recommended
If hardware zoning enforcement is preferred, edit the zoning database to have zoned PIDs for that
Action
port.
Severity
WARNING
Fabric OS Message Reference
53-1000437-01
Avoid having too many hosts zoned with a set of target devices at a single port.
Avoid having too many zones directed at a single port group on the switch.
<port number>
Out of CAM entries.
77
ZONE-1006
445

Advertisement

Table of Contents
loading

Table of Contents