51
PDM-1011
PDM-1011
Message
<timestamp>, [PDM-1011], <sequence-number>,, WARNING, <system-name>, File read
failed: <file name>
Probable Cause
Indicates that the parity data manager (PDM) process could not read data from the specified file.
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
PDM-1012
Message
<timestamp>, [PDM-1012], <sequence-number>,, WARNING, <system-name>, File write
failed: <file name>
Probable Cause
Indicates that the parity data manager (PDM) process could not write data to the specified file.
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
PDM-1013
Message
<timestamp>, [PDM-1013], <sequence-number>,, WARNING, <system-name>, File empty:
<File Name>
Probable Cause
Indicates that the switch configuration file /etc/fabos/fabos.[0|1].conf is empty.
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
PDM-1014
Message
<timestamp>, [PDM-1014], <sequence-number>,, WARNING, <system-name>, Access
sysmod failed.
Probable Cause
Indicates that a system call to sysMod failed.
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
306
Fabric OS Message Reference
53-1000437-01