Fcr-1059; Fcr-1060; Fcr-1061 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Recommended
Please check the switches on both ends of the link for a possible mismatch in switch or port
Action
configuration parameters such as 'Operating Mode', EDTOV, or RATOV.
Run the portCfgExport command to modify the appropriate parameters on the local switch.
Run the appropriate configuration command to modify the switch or port parameters on the
remote switch.
Severity
WARNING

FCR-1059

Message
<timestamp>, [FCR-1059], <sequence-number>,, INFO, <system-name>, EX_Port
number>
Probable Cause
Indicates that the authentication, which uses the Diffie Hellman - challenge handshake
authentication Protocol (DH-CHAP), failed on the EX_Port.
Recommended
Verify that the shared secrets on both sides of the link match.
Action
Disable and enable the ports by using the portDisable and the portEnable commands to restart
authentication.
Severity
INFO

FCR-1060

Message
<timestamp>, [FCR-1060], <sequence-number>,, WARNING, <system-name>,
EX_Port(
Probable Cause
Indicates that virtual channel (VC) Link Init is enabled on the local switch and the remote switch is
negotiating in R_RDY mode. The fabric might not form properly.
Recommended
Check the configuration on the local switch using the portCfgShow command to verify that the VC
Action
Link Init is disabled, if the remote switch is configured in R_RDY mode or only capable of R_RDY
mode.
VC_RDY mode: Virtual-channel flow control mode. This is a proprietary protocol.
R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol, that
uses R_RDY primitive for flow control.
Severity
WARNING

FCR-1061

Message
<timestamp>, [FCR-1061], <sequence-number>,, INFO, <system-name>, Backbone fabric
created on port
Probable Cause
Indicates that a backbone fabric was built on the specified port.
Fabric OS Message Reference
53-1000437-01
was disabled due to an authentication failure.
<port number>
) has an incompatible configuration setting.
<port number>
.
20
FCR-1059
<port
131

Advertisement

Table of Contents
loading

Table of Contents