SYSM-1004

SYSM-1004
Message
<timestamp>, [SYSM-1004], <sequence-number>,, ERROR, <system-name>, Failed to
retrieve current chassis configuration option, ret=
Probable Cause
Indicates that there was a failure to read configuration data from the WWN card.
Recommended
Verify that the world-wide name (WWN) card is present and operational and that the affected
Action
control processor (CP) is properly seated in its slot.
Severity
ERROR

SYSM-1005

Message
<timestamp>, [SYSM-1005], <sequence-number>, FFDC, CRITICAL, <system-name>, CP
blade in slot
Probable Cause
Indicates that there was a failure to read the chassis type from the system.
Recommended
Verify that the control processor (CP) blade is operational and is properly seated in its slot.
Action
Severity
CRITICAL

SYSM-1006

Message
<timestamp>, [SYSM-1006], <sequence-number>, FFDC, CRITICAL, <system-name>, CP
blade in slot
Probable Cause
Indicates that this chassis type is not compatible with the control processor (CP) blade.
Recommended
Use the CP blade on a compatible chassis.
Action
Severity
CRITICAL

SYSM-1007

Message
<timestamp>, [SYSM-1007], <sequence-number>,, WARNING, <system-name>, PERMITTING
USE OF INCOMPATIBLE CHASSIS FOR CP IN SLOT
RESULT.
Probable Cause
Over-riding the incompatible control processor (CP)/chassis check. For engineering use only
Recommended
Delete the /var/chassis_backplane_override file and reboot the CP.
Action
Severity
WARNING
420
<Slot number>
failed to retrieve current chassis type.
<Slot number>
is incompatible with the chassis type.
<Unknown>
<Slot number>
. DATA ERRORS MAY
Fabric OS Message Reference
53-1000437-01