Pdm-1004; Pdm-1005; Pdm-1006; Pdm-1007 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

51

PDM-1004

PDM-1004
Message
<timestamp>, [PDM-1004], <sequence-number>,, WARNING, <system-name>, PDM memory
shortage.
Probable Cause
Indicates that the parity data manager (PDM) process ran out of memory.
Recommended
Reboot or power cycle the switch.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING

PDM-1005

Message
<timestamp>, [PDM-1005], <sequence-number>,, WARNING, <system-name>, FSS register
failed.
Probable Cause
Indicates that the parity data manager (PDM) failed to register with the Fabos synchronization
service (FSS).
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING

PDM-1006

Message
<timestamp>, [PDM-1006], <sequence-number>,, WARNING, <system-name>, Too many
files in sync.conf.
Probable Cause
Indicates that the configuration file sync.conf contains too many entries.
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING

PDM-1007

Message
<timestamp>, [PDM-1007], <sequence-number>,, WARNING, <system-name>, File not
created:
Probable Cause
Indicates that the parity data manager (PDM) process failed to create the specified file.
304
<file name>.
Fabric OS Message Reference
53-1000437-01

Advertisement

Table of Contents
loading

Table of Contents