20
FCR-1069
Severity
INFO
FCR-1069
Message
<timestamp>, [FCR-1069], <sequence-number>,, INFO, <system-name>, The FC Routing
service is enabled.
Probable Cause
Indicates that the FC Routing service is enabled. This is caused by either fosConfig –-enable fcr, or
a configDownload with the fcrState set to 1 (enabled). Note that the FC Routing service is disabled
by the factory.
Recommended
No action is required.
Action
Severity
INFO
FCR-1070
Message
<timestamp>, [FCR-1070], <sequence-number>,, INFO, <system-name>, The FC Routing
configuration is set to default.
Probable Cause
Indicates that the FC Routing configuration is set to default by user. This removes all prior FC
Routing configurations.
Recommended
No action is required.
Action
Severity
INFO
FCR-1071
Message
<timestamp>, [FCR-1071], <sequence-number>,, INFO, <system-name>, Port
number>
Probable Cause
Indicates that the port became an EX_Port or VEX_Port.
Recommended
No action is required.
Action
Severity
INFO
FCR-1072
Message
<timestamp>, [FCR-1072], <sequence-number>,, INFO, <system-name>, Port
number>
Probable Cause
Indicates that the port is no longer an EX_Port or VEX_Port.
134
is changed from non FCR port to FCR port.
is changed from FCR port to non FCR port.
<port
<port
Fabric OS Message Reference
53-1000437-01