SCN System Messages

SCN-1001

Message
<timestamp>, [SCN-1001], <sequence-number>, FFDC, CRITICAL, <system-name>, SCN
queue overflow for process
Probable Cause
Indicates that an attempt to write a state change notification (SCN) message to a specific queue
has failed because the SCN queue for the specified daemon name is full. This might be caused by
the daemon hanging or if the system is busy.
The valid values for daemon name can be:
Recommended
If this message is caused by the system being busy, the condition is temporary.
Action
If this message is caused by a hung daemon, the software watchdog will cause the daemon to
dump the core and reboot the switch.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
CRITICAL
Fabric OS Message Reference