27

FW-1047

FW-1047
Message
<timestamp>, [FW-1047], <sequence-number>,, WARNING, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high
boundary. The supplied current of the SFP transceiver is outside of the normal range, indicating
possible hardware failure.
Recommended
If the current rises above the high boundary, you must replace the SFP.
Action
Severity
WARNING

FW-1048

Message
<timestamp>, [FW-1048], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the
Action
end-user installation.
Severity
INFO

FW-1049

Message
<timestamp>, [FW-1049], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has changed. Frequent
voltage fluctuations are an indication that the SFP is deteriorating.
Recommended
Replace the SFP if you see frequent voltage fluctuations.
Action
Severity
INFO