Sec-1331 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

63

SEC-1331

Recommended
Verify that the distribution is initiated by the primary FCS switch. Use the secPolicyShow command
Action
to verify and correct the configuration if necessary.
Severity
ERROR
SEC-1331
Message
<timestamp>, [SEC-1331], <sequence-number>,, ERROR, <system-nam>, Attempt to
enable secure mode failed. Reason: <Reason>.
Probable Cause
Indicates that the secModeEnable command failed on the fabric, because default IP Filter policies
are not active on the switch, or an active transaction exists on IP Filter policies.
Recommended
Verify that the security event was planned. If the security event was planned, run the ipfilter
Action
--activate default_ipv4 or the ipfilter --activate default_ipv6 command to activate default IP
Filter Policies. Use the ipfilter --save or the ipfilter --transabort commands to save or abort any
active transaction on IP Filter policies. Then retry the secModeEnable command.
Severity
ERROR
394
Fabric OS Message Reference
53-1000437-01

Advertisement