Ts-1006; Ts-1007 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

72

TS-1006

TS-1006
Message
<timestamp>, [TS-1006], <sequence-number>,, INFO, <system-name>,
Probable Cause
Indicates that a time service event is occurring or has failed. The message might be one of the
following:
Recommended
No action is required.
Action
Severity
INFO

TS-1007

Message
<timestamp>, [TS-1007], <sequence-number>,, WARNING, <system-name>,
Probable Cause
Indicates that a switch is trying to set the tsclockserver, which is not the primary fabric
configuration server (FCS) across the fabric. A consistent FCS policy must be implemented across
the fabric.
Recommended
Verify that the FCS policy is consistent across the fabriclog_ts.xml.
Action
Severity
INFO
430
Init failed. Time Service exiting
Probable Cause: Initialization error, Time Server exits.
Synchronizing time of day clock
Probable Cause: Usually logged during temporary operational issues when the clock goes out
of synchronization: For example, when a time update packet is missed due to fabric
reconfiguration or role change of the principal or primary fabric configuration server (FCS)
switch. If the message does not recur, it should be ignored.
Validating time update
Probable Cause: Usually logged during temporary operational issues when a time update
packet cannot be validated in a secure fabric. For example, during fabric reconfiguration or
role change of the primary FCS switch. If the message does not recur, it should be ignored.
<message>
<message>
Fabric OS Message Reference
53-1000437-01