Mfic-1001; Mfic-1002; Mfic System Messages - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

MFIC System Messages

MFIC-1001

Message
<timestamp>, [MFIC-1001], <sequence-number>,, ERROR, <system-name>, failure at
sysmod_scn registry rc=
Probable Cause
Indicates that the system is temporarily out of resources.
Recommended
No action is required; this message is often transitory.
Action
If the message persists, run a switch reboot or an haFailover (if applicable).
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR

MFIC-1002

Message
<timestamp>, [MFIC-1002], <sequence-number>,, INFO, <system-name>, Chassis FRU
header not programmed for switch NID, using defaults (applies only to FICON
environments).
Probable Cause
Indicates that custom switch node descriptor (NID) fields have not been programmed in nonvolatile
storage. The default values are used. The Switch NID is used only in the following SB ELS frames:
Request Node Identification Data (RNID) and Registered Link Incident Record (RLIR).
The use of SB-3 link incident registration and reporting is typically limited to FICON environments.
Recommended
No action is required if SB-3 link incident registration and reporting is not used by the host or if
Action
default values are desired for the switch node descriptor fields.
Severity
INFO
Fabric OS Message Reference
53-1000437-01
<failure reason>
Chapter
45
287

Advertisement