SEC-1173
Message
<timestamp>, [SEC-1173], <sequence-number>,, ERROR, <system-name>, Lost contact
with Primary FCS switch.
Probable Cause
Indicates that the switch has lost contact with the primary fabric configurations server (FCS) switch
in the secure fabric. This could be due to the primary FCS being disabled.
Recommended
If the primary FCS was disabled intentionally, no action is required; if not, check the primary FCS.
Action
Severity
ERROR
SEC-1174
Message
<timestamp>, [SEC-1174], <sequence-number>,, ERROR, <system-name>, Failed to set
<FCS or non-FCS>
Probable Cause
Indicates that the FCS or non-FCS password could not be set.
Recommended
Verify that all switches in the fabric are in time synchronization with the primary and that no
Action
external entity is trying to access the fabric. When verification is complete, retry the operation.
Severity
ERROR
SEC-1175
Message
<timestamp>, [SEC-1175], <sequence-number>,, ERROR, <system-name>, Failed to
install zone data.
Probable Cause
Indicates that the zone database could not be installed on the switch.
Recommended
Verify that all switches in the fabric are in time synchronization with the primary and that no
Action
external entity is trying to access the fabric. When verification is complete, retry the operation.
Severity
ERROR
SEC-1176
Message
<timestamp>, [SEC-1176], <sequence-number>,, ERROR, <system-name>, Failed to
generate new version stamp.
Probable Cause
Indicates that the primary fabric configurations server (FCS) failed to generate a new version stamp
due to the fabric not being stable.
Recommended
Verify that all switches in the fabric are in time synchronization with the primary and that no
Action
external entity is trying to access the fabric. When verification is complete, retry the operation.
Severity
ERROR
Fabric OS Message Reference
53-1000437-01
password.
63
SEC-1173
375