FW-1116

Message
<timestamp>, [FW-1116], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause
Indicates that the number of times E_Ports have gone down has changed from a value outside of
the acceptable range to a value within the acceptable range. E_Ports go down each time you
remove a cable or small form-factor pluggable (SFP). SFP failures also cause E_Ports to go down.
E_Port downs might be caused by transient errors.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the
Action
end-user installation.
Severity
INFO

FW-1117

Message
<timestamp>, [FW-1117], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause
Indicates that the number of fabric reconfigurations has changed. The following actions can cause
a fabric reconfiguration:
Recommended
Verify that the cable is properly connected at both ends. Verify that the small form-factor
Action
pluggables (SFPs) have not become faulty. An inexplicable fabric reconfiguration might be a
transient error and might not require troubleshooting.
Severity
INFO
Fabric OS Message Reference
53-1000437-01
two switches with the same domain ID have connected to one another.
two fabrics have joined.
an E_Port has gone offline.
a principal link has segmented from the fabric.