63
SEC-1117
SEC-1117
Message
<timestamp>, [SEC-1117], <sequence-number>,, INFO, <system-name>, Fail to set
<data>
Probable Cause
Indicates that the switch failed to save the data received by the primary fabric configurations
server (FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or
multiple user authentication data.
Recommended
Run the secFabricShow command to verify that all switches in fabric are in the ready state. When
Action
all switches are in the ready state, retry the operation.
Severity
INFO
SEC-1118
Message
<timestamp>, [SEC-1118], <sequence-number>,, INFO, <system-name>, Fail to set
SNMP string.
Probable Cause
Indicates that the SNMP string could not be set.
Recommended
Usually this problem is transient. Retry the command.
Action
Severity
INFO
SEC-1119
Message
<timestamp>, [SEC-1119], <sequence-number>,, INFO, <system-name>, Secure mode has
been enabled.
Probable Cause
Indicates that the secure Fabric OS was enabled by the secModeEnable command.
Recommended
Verify that the security event was planned. If the security event was planned, there is no action
Action
required. If the security event was not planned, take appropriate action as defined by your
enterprise security policy.
Severity
INFO
364
.
Fabric OS Message Reference
53-1000437-01