Sulb-1017; Sulb-1010; Sulb-1018; Sulb-1020 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

83

SULB-1010

SULB-1010
Message
AUDIT, <timestamp>, [SULB-1010], INFO, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwarecommit failed (status=0x
Probable Cause
Indicates that the firmwareCommit failed. The error code provides debugging information. See
Table 11
Recommended
If the failure is caused by an inconsistent filesystem, contact your switch service provider.
Action
Severity
INFO

SULB-1017

Message
AUDIT, <timestamp>, [SULB-1017], ERROR, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwaredownload failed in slot
Probable Cause
Indicates that firmwareDownload failed in the specified blade. The error may be caused by an
inconsistent AP blade firmware stored on the active CP. It may also caused by an internal Ethernet
issue or by a persistent storage hardware failure.
Recommended
Run the slotShow command. If the blade is in FAULTY state, run the slotPowerOff and slotPowerOn
Action
commands to trigger another firmwareDownload to the blade. If the blade is stuck in LOADING
state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists,
contact your switch service provider.
Severity
ERROR

SULB-1018

Message
AUDIT, <timestamp>, [SULB-1018], ERROR, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwaredownload timed out in slot
Probable Cause
The error may be caused by a blade initialization issue after the new firmware is downloaded and
the blade is rebooted. The error may also be caused by an internal Ethernet issue or by a persistent
storage failure.
Recommended
Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and
Action
slotPowerOn commands to trigger another firmwareDownload. If the blade is stuck in LOADING
state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists,
contact your switch service provider.
Severity
ERROR

SULB-1020

Message
AUDIT, <timestamp>, [SULB-1020], ERROR, FIRMWARE, <event-initiator-details>,
<event-location>, , New firmware failed to boot in slot
488
for more information.
<error code>
).
<Slot number>
.
<Slot number>
.
<Slot number>
.
Fabric OS Message Reference
53-1000437-01

Advertisement

Table of Contents
loading