EM-1018

Message
<timestamp>, [EM-1018], <sequence-number>, FFDC, CRITICAL, <system-name>, CP
blade in slot <slot number> failed to retrieve current chassis type (<detailed
fault descriptor>/<PLACE HOLDER>/0x<PLACE HOLDER>).
Probable Cause
Indicates that there was a failure to read the chassis type from the system.
Recommended
Verify that the control processor (CP) blade is operational and is properly seated in its slot.
Action
Severity
CRITICAL

EM-1019

Message
<timestamp>, [EM-1019], <sequence-number>,, WARNING, <system-name>, Current
chassis configuration option (
is not compatible with standby firmware version (Pre 4.4), cannot allow HA Sync.
Probable Cause
Indicates that the current chassisConfig option is not supported by the firmware on the standby
control processor (CP). This is true even if the standby comes up and appears to be operational.
High availability (HA) synchronization of the CPs will not be allowed.
Recommended
Either change the chassisConfig option to 1 with the chassisConfig command, or upgrade the
Action
firmware on the standby to the version running on the active CP.
Severity
WARNING

EM-1028

Message
<timestamp>, [EM-1028], <sequence-number>, FFDC, CRITICAL, <system-name>, HIL
Error: <function> failed to access history log for FRU: <FRU Id> (rc=<return
code>).
Probable Cause
Indicates a problem accessing the data on the world-wide name (WWN) card field-replaceable unit
(FRU), or the WWN card storage area on the main logic board.
The problems were encountered when the software attempted to write to the history log storage to
record an event for the specified FRU. The return code is for internal use only. This is a serious
hardware problem.
The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot,
or port.
Recommended
If the message persists, reboot or power cycle the switch.
Action
If the message still persists, replace the WWN card, or the switch (for nonbladed switches).
Severity
CRITICAL
Fabric OS Message Reference
53-1000437-01
<Chassis config option currently in effect>
11
EM-1018
)
77