AUTH-3007
Message
AUDIT, <timestamp>, [AUTH-3007], INFO, SECURITY, <event-initiator-details>,
<event-location>, , Event: <Event Name>, Status: failed, Info: Port <port number>
disabled due to receiving an authentication reject with code '<Reason String>' and
explanation '<Explanation String>'.
Probable Cause
Indicates that the specified port was disabled due to receiving an authentication reject response
from the connected switch/device.
The error might indicate that an invalid entity attempted to connect to the switch.
Recommended
Check the connection port for a possible security attack.
Action
Check the shared secrets using secAuthSecret and reinitialize authentication using the portDisable
and portEnable commands.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
INFO
AUTH-3008
Message
AUDIT, <timestamp>, [AUTH-3008], INFO, SECURITY, <event-initiator-details>,
<event-location>, , Event: <Event Name>, Status: failed, Info: Port <port number>
has been disabled due to authentication failure with code '<Reason String>' and
explanation '<Explanation String>'.
Probable Cause
Indicates that the specified port has been disabled, because the connecting switch/device failed to
authenticate.
The error might indicate that an invalid entity attempted to connect to the switch.
Recommended
Check the connection port for a possible security attack.
Action
Check the shared secrets using secAuthSecret and reinitialize authentication using the portDisable
and portEnable commands.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.