Fss-1006; Fss-1007 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

FSS-1006

Message
<timestamp>, [FSS-1006], <sequence-number>,, WARNING, <system-name>, No FSS
message available
Probable Cause
Indicates that data is not available on the Fabric OS state synchronization (FSS) device.
Recommended
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
Action
supportSave command and contact your switch service provider.
Severity
WARNING

FSS-1007

Message
<timestamp>, [FSS-1007], <sequence-number>,, CRITICAL, <system-name>,
<component name>
Probable Cause
Indicates that the Ethernet connection between the active control processor (CP) and standby CP is
not healthy. The error occurs when the standby CP does not respond to a request from the active
CP within 5 seconds. This usually indicates a problem with the internal Ethernet connection and a
disruption of the synchronization process.
Recommended
Check the Ethernet connection between active CP and standby CP (interface eth1) by issuing net
Action
commands such as ifconfig eth1 (as root) or run supportShow/supportSave to validate the network
configuration; then try to restore the synchronization by issuing the haSyncStart command. If the
problem persists, contact your switch service provider.
Severity
CRITICAL
Fabric OS Message Reference
53-1000437-01
: Faulty Ethernet connection.