Sec-1046; Sec-1049; Sec-1050 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference

Brocade fabric os message reference - supporting fabric os v5.3.0 (53-1000437-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

SEC-1046

Message
<timestamp>, [SEC-1046], <sequence-number>,, ERROR, <system-name>, Empty list.
Probable Cause
Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
Action
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR

SEC-1049

Message
<timestamp>, [SEC-1049], <sequence-number>,, ERROR, <system-name>, Invalid switch
name
Probable Cause
Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
Action
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR

SEC-1050

Message
<timestamp>, [SEC-1050], <sequence-number>,, ERROR, <system-name>, There are more
than one switches with the same name
Probable Cause
Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
Action
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR
Fabric OS Message Reference
53-1000437-01
<switch name>
.
<switch name>
in the fabric.
63
SEC-1046
345

Advertisement

Table of Contents
loading

Table of Contents