MS-1009

MS-1009
Message
<timestamp>, [MS-1009], <sequence-number>,, ERROR, <system-name>, RLIR event.
Switch Port ID is <PID> (<PID (hex)>). Device Port Tag is <port tag>. <message
text>.
Probable Cause
Indicates a registered link incident record (RLIR) has been generated for one of the actions
indicated by the <message>.
The following messages will be displayed:
Recommended
Persistent RLIR incidents are likely the result of SAN hardware problems such as bad cables or
Action
small form-factor pluggables (SFPs). It may be necessary to replace hardware if these messages
persist.
Severity
ERROR

MS-1021

Message
<timestamp>, [MS-1021], <sequence-number>,, ERROR, <system-name>, MS WARMBOOT
failure(FSS_MS_WARMINIT failed. Reason=<failure reason>).
Probable Cause
Indicates the Fabric OS state synchronization (FSS) warm recovery failed during the WARM INIT
phase of a reboot.
Recommended
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
Action
supportSave command and contact your switch service provider.
Severity
ERROR

MS-1022

Message
<timestamp>, [MS-1022], <sequence-number>,, INFO, <system-name>, Management
Server Platform Service <Activated or Deactivated>.
Probable Cause
Indicates Management Server Platform Service is being activated or deactivated.
Recommended
No action is required.
Action
Severity
INFO
362
Exceeded bit error rate threshold
Loss of signal or synchronization
Not operational seq. recognized
Primitive sequence timeout
Unrecognized link incident
Fabric OS Message Reference