Fcdomain Initiation; Fabric Name; Incoming Rcfs - Cisco DS-X9530-SF1-K9 - Supervisor-1 Module - Control Processor Configuration Manual

Mds 9000 family
Table of Contents

Advertisement

fcdomain Initiation

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
fcdomain Initiation
By default, the fcdomain feature is enabled on each switch. If you disable the fcdomain feature in a
switch, that switch can no longer participate with other switches in the fabric. The fcdomain
configuration is applied to runtime through a disruptive restart.
To disable fcdomains in a single VSAN or a range of VSANs, follow these steps:
Command
Step 1
switch# config t
switch(config)#
Step 2
switch(config)# no fcdomain vsan 7-200
switch(config)# fcdomain vsan 2008

Fabric Name

By default the configured fabric name is 20:01:00:05:30:00:28:df.
The fabric name is applied to runtime through a disruptive restart when the fcdomain is configured as
disabled (see the
To set the fabric name value for a disabled fcdomain, follow these steps:
Command
Step 1
switch# config t
switch(config)#
Step 2
switch(config)# fcdomain fabric-name
20:1:ac:16:5e:0:21:01 vsan 3
switch(config)# no fcdomain fabric-name
20:1:ac:16:5e:0:21:01 vsan 3010

Incoming RCFs

The rcf-reject option is configured on a per-interface, per-VSAN basis. By default, the rcf-reject option
is disabled (that is, RCF request frames are not automatically rejected).
The rcf-reject option takes effect immediately. No fcdomain restart is required.
To stop incoming RCF request frames, follow these steps:
Command
Step 1
switch# config t
switch(config)#
Step 2
switch(config)# interface fc1/1
switch(config-if)#
Cisco MDS 9000 Family Configuration Guide
14-8
When the fcdomain feature is disabled, the runtime fabric name is the same as the configured fabric
name.
When the fcdomain feature is enabled, the runtime fabric name is the same as the principal switch's
WWN.
"Domain Restart" section on page
Chapter 14
Purpose
Enters configuration mode.
Disables the fcdomain configuration in VSAN 7
through 200.
Enables the fcdomain configuration in VSAN 2008.
14-3).
Purpose
Enters configuration mode.
Assigns the configured fabric name value in VSAN 3.
Changes the fabric name value to the factory default
(20:01:00:05:30:00:28:df) in VSAN 3010.
Purpose
Enters configuration mode.
Configures the specified interface.
OL-6973-03, Cisco MDS SAN-OS Release 2.x
Configuring Domain Parameters