Configuring Domain Parameters
The Fibre Channel domain (fcdomain) feature performs principal switch selection, domain ID
distribution, FC ID allocation, and fabric reconfiguration functions as described in the FC-SW-2
standards. The domains are configured on a per VSAN basis. If you do not configure a domain ID, the
local switch uses a random ID.
Caution
Changes to fcdomain parameters should not be performed on a daily basis. These changes should be
made by an administrator or individual who is completely familiar with switch operations.
When you change the configuration, be sure to save the running configuration. The next time you reboot
Tip
the switch, the saved configuration is used. If you do not save the configuration, the previously saved
startup configuration is used.
This chapter includes the following sections:
About fcdomain Phases, page 14-2
Domain Restart, page 14-3
Domain Configuration, page 14-4
Switch Priority, page 14-6
Allowed Domain ID Lists, page 14-6
Merged Stable Fabrics, page 14-7
Contiguous Domain Assignments, page 14-7
fcdomain Initiation, page 14-8
Fabric Name, page 14-8
Incoming RCFs, page 14-8
Persistent FC IDs, page 14-9
Persistent FC IDs Manual Configuration, page 14-10
Persistent FC ID Selective Purging, page 14-13
Displaying fcdomain Information, page 14-13
Default Settings, page 14-16