Cisco DS-X9530-SF1-K9 - Supervisor-1 Module - Control Processor Configuration Manual page 252

Mds 9000 family
Table of Contents

Advertisement

Identifying Module LEDs
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
Table 10-6
Table 10-6
LED
Status
System
MGMT 10/100
Ethernet Link
LED
MGMT 10/100
Ethernet
Activity LED
Cisco MDS 9000 Family Configuration Guide
10-12
describes the LEDs for the Cisco MDS 9200 Series interface module.
LEDs on the Cisco MDS 9200 Series Interface Module
Status
Description
Green
All diagnostics pass. The module is operational (normal initialization
sequence).
Orange The module is booting or running diagnostics (normal initialization
sequence).
or
The inlet air temperature of the system has exceeded the maximum system
operating temperature limit (a minor environmental warning). To ensure
maximum product life, you should immediately correct the environmental
temperature and restore the system to normal operation.
Red
The diagnostic test failed. The module is not operational because a fault
occurred during the initialization sequence.
or
he inlet air temperature of the system has exceeded the safe operating
T
temperature limits of the card (a major environmental warning). The card
has been shut down to prevent permanent damage.
Green
All chassis environmental monitors are reporting OK.
Orange The power supply failed or the power supply fan failed.
or
Incompatible power supplies are installed.
or
The redundant clock failed.
Red
The temperature of the supervisor module exceeded the major threshold.
Green
Link is up.
Off
No link.
Green
Traffic is flowing through port.
Off
No link or no traffic.
Chapter 10
Managing Modules
OL-6973-03, Cisco MDS SAN-OS Release 2.x

Advertisement

Table of Contents
loading

Table of Contents