Cisco DS-X9530-SF1-K9 - Supervisor-1 Module - Control Processor Configuration Manual page 786

Mds 9000 family
Table of Contents

Advertisement

Configuring iSCSI
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
In this mode, only one virtual host N port (HBA port) is created per IPS port. All the iSCSI hosts
connecting to that IPS port will be multiplexed using the same virtual host N port (see
This mode simplifies the task of statically binding WWNs. LUN mapping and assignment on the Fibre
Channel storage array must be configured to allow access from the proxy virtual N port's pWWN for all
LUNs used by each iSCSI initiator which connects through this IPS port. The LUN is then assigned to
each iSCSI initiator by configuring iSCSI virtual targets (see the
with LUN mapping and iSCSI access control (see the
Figure 35-11 Multiplexing IPS Ports
Host A
iSCSI
iSCSI
Host B
iSCSI
iSCSI
Host C
iSCSI
iSCSI
Proxy initiator mode can be configured on a per IPS port basis, in which case only iSCSI initiators
terminating on that IPS port will be in this mode.
When a IPS port is configured in proxy-initiator mode, Fabric Login (FLOGI) is done via the virtual
iSCSI interface of the IPS port. After the FLOGI is completed, the proxy-initiator virtual N port is
on-line in the Fibre Channel Fabric and virtual N port is registered in the Fibre Channel Name Server.
The IPS module or MPS-14/2 module registers the following entries in the Fibre Channel Name Server:
Similar to transparent initiator mode, user can provide a pWWN and nWWN or request a system
assigned WWN for the proxy initiator N port.
To configure the proxy initiator, follow these steps:
Command
Step 1
switch# config terminal
switch(config)#
Step 2
switch(config)# interface iscsi 4/1
switch(config-if)#
Cisco MDS 9000 Family Configuration Guide
35-16
MDS
IP network
iSCSI interface name iSCSI slot /port is registered in the symbolic-node-name field Name Server
SCSI_FCP in the FC-4 type field of the name server
Initiator flag in the FC-4 feature of the name server
Vendor specific flag (iscsi-gw) in the FC-4 type field to identify the N-port device as a iSCSI
gateway device in the name server
"iSCSI Access Control" section on page
Proxy initiator
host
Purpose
Enters configuration mode.
Selects the iSCSI interface on the switch that
initiators will connect to.
Chapter 35
Configuring iSCSI
Figure
"Static Mapping" section on page
OL-6973-03, Cisco MDS SAN-OS Release 2.x
35-11).
35-7)
35-19).