While hay, straws collection or working in areas with increased fire danger do not
allow build-up of inflammable materials on the silencer guards or connecting gas lines.
During daily maintenance, it is mandatory to perform following operations:
- visually inspect condition of the electric wiring, wire harnesses in the engine com-
partment, in the cab front wall area and visible parts for signs of rubbing, melting or exter-
nal insulation damage. If any of above defects are discovered, take measures to remedy
discovered insulation damages and remove the cause of such insulation damage;
- visually inspect elements of the hydraulic system. If condensations and leakages
are found, remedy them by tightening the threaded connections. Replace high-pressure
hoses with cracks, cuts or damages.
To prevent the tractor electric wiring burning, newer use fuses with higher nominal
current values, which are above stated in subsection2.22 "Electric fuses and electromag-
netic relays".
IT IS PROHIBITED TO INSTALL JUMPER WIRES AND OTHER HOMEMADE
CURRENT-CARRYING ELEMENTS INSTEAD OF THE FUSES.
When the tractor is stopped, deactivate the AB switch.