3.3
Installation
Install the unit parts of the starter kit to the printer according to the follow-
ing procedures:
3.3.1
magicolor 6100 Series Service Manual
Procedures for Installation of Cleaning Roller and Oil Bottle
(see Fig. 3-5 to Fig. 3-8).
Note: If a duplexer is installed, open the top cover of the duplexer first.
1. Open the paper exit unit.
2. Open the oil bottle and cleaning
roller lock levers. Move the ten-
sion-release levers (left and right)
to the normal operating position
(center).
3. Install the oil bottle into the fusing
unit.
4. Close the retainer lock lever.
5. Install the cleaning roller in the
fusing unit.
6. Close the cleaning roller
retainer lock lever.
7. Close the paper exit unit.
Note:
Fuser Oil Bottle
Cleaning Roller
Tension-Release
Lever
Cleaning Roller Lock Lever
Paper Exit Unit
Fuser
Fig. 3-5
Fig. 3-6
Lock Lever
Fig. 3-7
Oil Bottle Lock Lever
Fig. 3-8
Page 3-9