5.3.4
magicolor 6100 Series Service Manual
Replacement of the Transfer Roller
5.3.4.1
Criterion of Replacement
The transfer roller should be replaced with a new transfer roller according
to the periodic maintenance cycle set out in the Table 5-4. When it is time
to replace the transfer roller, the warning code "120K CHECKUP" will
appear in the operator panel.
5.3.4.2
Purpose of Replacement
To prevent image degradation due to the deterioration of the transfer
roller.
5.3.4.3
Tools and Supplies:
1. Lint-free cloth.
1. Transfer unit (one)
5.3.4.4
Procedures
5.3.4.4.1
1.
2.
Transfer Roller
ADMINISTRATION/CONSUMABLES/ITEM
REPLACED/ FUSER.
Sequence of Disassembling
After turning off the power, remove the power cord from the
outlet.
Open the transfer door.
Fig. 5-20
Transfer Roller
Lock Lever
Page 5-19