Transfer Roller
Fig. 5-21
Page 5-20
5.3.4.4.2
Procedures of Replacement
1.
Move the two lock levers in the 'A' direction (see Fig. 5-22).
2.
While holding the lock levers, pull up the transfer roller.
Transfer Roller
Lock Lever
5.3.4.4.3
Assembly Procedures
1.
While holding the lock levers, align the shaft of both sides to
the groove in the transfer base.
2.
Press in the shaft of the transfer roller into the groove.
3.
Move the lock lever in the 'B' direction, and secure the trans-
fer roller (see Fig. 5-22).
4.
Close the transfer door.
5.
Plug the power cord in the outlet.
6.
Push the power switch On.
7.
Upon completion of warming-up, clear the code "120K
CHECKUP" with Service Mode CLEAR CARE Mode or via
"ADMINISTRATION/CONSUMABLES/PM SERVICE/
120K PM SERVICE."
Lock Lever
A
Hole
B
Fig. 5-22