Adjustment Procedures - MINOLTA-QMS magicolor 6100 Series Service Manual

Table of Contents

Advertisement

6.5

Adjustment Procedures

6.5.1
magicolor 6100 Series Service Manual
Adjustment of Top and Left Margins
The top and left margins can be adjusted at the operator panel.
6.5.1.1
Purpose
If there is no top margin or left margin for the imageable area or when
MCTL PWB is replaced, the adjustment of top and left margins is
required.
6.5.1.2
Adjustment Procedure
1. Execute "GRID PRINT" in the SERVICE MODE.
2. Measure the position 'A' and 'B' of leading edge top margin.
(A + B) / 2 Default Value ð4.0 ±1.5mm
3. Measure the position 'C' and 'D' of left margin.
(C + D) / 2 Default Value ð3.0 ±1.5mm
4. If the specification value is not met, implement the following adjust-
ment. Execute "43 MARGIN ADJUST" in the FACTORY MODE.
5. After the above adjustment, execute "GRID PRINT" and confirm the
margin.
Left margin
C
D
Leading Edge
Imageable
Area
Fig. 6-4
Page 6-37