Step
Select CBV TUNE UP
1
The LCD changes as shown in (a) ---> (b)
After selecting CBV TUNE UP Code 5, press the Select
key.
2
The LCD changes as shown in (b) ---> (c)
Tune Up value can be adjusted by 9 increments between -4
and +4.
3
After selecting a given number, press the Select key.
The LCD changes as shown in (c)
Press the Media key to complete this procedure.
4
The LCD changes as shown in (c) ---> (d)
Page 6-30
6.4.3.8.6.4
Table 6-21: CBV Tune Up Procedure
Description of Procedure
CBV Tune Up
Note: These are factory settings and should not
be changed.
This mode is used when the image defects
attributing to OPC belt need to be improved.
An adjustment is made to the OPC belt bias
voltage against a reference value 0 (zero)
between a range of -4 and +4.
Message in LCD
39 FACTORY MODE
(a)
45 NVM TUNE UP
(b)
No.=< 1 2 3 4 5 6 7 8 9 >
45 CBV TUNE UP
(c)
-< 4 3 2 1 0 1 2 3 4 >+
45 NVM TUNE UP
(d)
No.=< 1 2 3 4 5 6 7 8 9 >
magicolor 6100 Series Service Manual
NVM TUNE UP