Step
Select ACV TUNE UP.
1
The LCD changes as shown in (a) ---> (b)
After selecting ACV TUNE UP Code 9, press the Select
key.
2
The LCD changes as shown in (b) ---> (c)
Tune Up value can be adjusted within 9 steps between the
step -4 and +4.
3
After selecting a given number, press the Select key.
The LCD changes as shown in (c)
Press the Media key to complete this procedure.
4
The LCD changes as shown in (c) ---> (d)
Page 6-32
6.4.3.8.6.6
Table 6-23: ACV Tune Up Procedure
Description of Procedure
ACV Tune Up
Note: These are factory settings and should not
be changed.
This mode shall be used to improve an
insufficient separation of the paper from the
transfer drum (when a winding jam has
occurred around the drum). By using this
mode, you can adjust the bias voltage of the
paper discharging output from he high voltage
power supply unit (HVU). This adjustment is
made between a range of -4 and +4.
Message in LCD
39 FACTORY MODE
(a)
45 ACV TUNE UP
(b)
No.=< 1 2 3 4 5 6 7 8 9 >
45 ACV TUNE UP
(c)
-< 4 3 2 1 0 1 2 3 4 >+
45 ACV TUNE UP
(d)
No.=< 1 2 3 4 5 6 7 8 9 >
magicolor 6100 Series Service Manual
ACV TUNE UP