Message Display
CHECK WASTE TONER
FUSER OIL EMPTY
FUSER OIL LOW
CHECK CLEANING ROLLER
x TONER MISINSTALLED
FUSER MISINSTALLED
BELT CARTRIDGE MIS-
INSTALLED
CLEANING ROLLER
MISINSTALLED
MISFEED JAM
INNER JAM
OUTER JAM
DRUM JAM
DUPLEX JAM
magicolor 6100 Series Service Manual
Table 8-1
Message Explanation
Either the waste toner pack is
full and needs to be replaced, or
it is incorrectly installed.
The oil bottle for the fuser is
empty. The printer will not print
any more copies until a new oil
bottle is installed.
The oil bottle for the fuser unit is
running low.
The cleaning roller needs to be
replaced.
The x (color) toner cartridge is
not installed properly.
The fuser is not fully seated.
The OPC belt cartridge is either
missing or incorrectly installed.
The fuser cleaning roller isn't
installed correctly.
Media has jammed between the
print engine and the input
cassette.
Media has jammed leaving the
OPC belt cartridge area.
Media has jammed between the
print engine and the output tray.
Media has jammed in the
transfer drum area.
Media has jammed in the
duplexer.
Countermeasure
Ensure that the waste toner pack
is not full and is correctly
installed.
Install a new fuser oil bottle.
Fuser oil is running low. A
limited number of copies (about
100) will still print. However,
when the oil runs out, the printer
stops and the FUSER OIL
EMPTY message appears.
Install a new cleaning roller.
Remove the toner cartridge and
reinstall.
Ensure the fuser is fully seated.
Ensure that an OPC belt
cartridge is correctly installed.
Remove and reinstall cleaning
roller.
Locate and remove the jam.
Locate and remove the jam.
Locate and remove the jam.
Locate and remove the jam.
Locate and remove the jam.
Page 8-5