5.2.2
magicolor 6100 Series Service Manual
Periodic Maintenance Cleaning Procedures
5.2.2.1
Cleaning of Registration Roller
The Registration Roller should be cleaned according to the periodic main-
tenance cleaning cycle presented in Table 5-3.
Tools:
Lint-free cotton cloth (2 ~ 3 pieces)
Cleaning Procedures (see Fig. 5-1 and Fig. 5-2):
1. Turn off the power supply, and unplug the power cord.
2. Open the transfer unit.
3. Using a clean, lint-free cloth, clean the registration roller incorporated
in the transfer unit.
Do not use alcohol or other solvents for cleaning the reg-
istration roller.
Registration
Roller
Registration
Roller
CAUTION
K
Y
M
C
Fig. 5-1
Fig. 5-2