7.3.8
Waster Toner Feeder Pipe
Fig. 7-39
Page 7-46
Ozone Fan (OZ FAN) / Ozone Duct Assembly
7.3.8.1
Tools
Phillips Screwdrivers #1 and #2
7.3.8.2
Disassembly Procedures
(see Fig. 7-39 and Fig. 7-40)
1. Remove the right side cover (see section 7.1.2).
2. Remove the right base cover (see section 7.1.10).
3. Remove three fixing screws (ST3x6) from the stay (R).
4. Remove the stay (R) from the frame.
5. Remove the ozone fan duct.
6. Disconnect the ozone fan connector (DCN5) from the IOS2 P.W.B.
7. Remove one fixing screw (ST3x6) from the ozone fan case.
8. Remove the ozone fan case.
9. Open the ozone fan case, and remove the ozone fan motor.
Ozone Fan
Case A'ssy
Exhaust Side
7.3.8.3
Assembly Procedures
1. Reassemble in reverse order of disassembly.
Ozone Fan
Ozone Fan Case
Ozone Fan Duct
Fig. 7-40
magicolor 6100 Series Service Manual
Stay (R)
Exhaust Side