MINOLTA-QMS magicolor 6100 Series Service Manual page 278

Table of Contents

Advertisement

7.6.9
Page 7-78
Fuser Connector
7.6.9.1
Tools
Phillips Screwdrivers #1 and #2
7.6.9.2
Disassembly Procedures
(see Fig. 7-70)
1. Remove the fuser.
2. Remove the left side cover (see section 7.1.3).
3. Remove the shield case A assembly (see section 7.2.5.2[13]).
4. Remove the connector (BCN2) from the high voltage power supply.
5. Remove two set screws (SP3x8) from the fuser connector. Note that
the set screw for the fuser connector is unique.
6. Remove the fuser connector.
7.6.9.3
Assembly Procedures
1. Install a new fuser connector.
2. Reassemble in reverse order of disassembly.
Fuser Connector
PH
PN
BCN2
Frame Assembly
Fig. 7-70
magicolor 6100 Series Service Manual

Advertisement

Table of Contents
loading

Table of Contents