Step
At "NEXTCARE INFO," press the Select Key.
1
The LCD changes as shown in (a) ---> (b)
Using the Scroll key, select the desired information.
The LCD changes as shown in (b)
Codes for Next Care are as follows:
2
2: Fuser Cleaning Roller (FC)
7: Belt Cartridge (BL)
8: Fuser Unit (FU)
9: Transfer Drum (TD)
10: Replacement Kit every 240K (OW)
After selecting the desired information code, press the
Select key. Then, the number of images or pages
3
corresponding to the selected code is displayed.
The LCD changes as shown in (b) ---> (c) through (g)
To clear screens (c) through (g) press the Media key
several times.
4
Press the Media key again at screen (b) to return to the
Service Mode.
The LCD changes as shown in (b) ---> (a)
Page 6-14
6.4.3.2
Next Care Information
Information about the replacement of maintenance parts can be obtained
here, including the number of pages printed.
Table 6-5: Next Care Procedure
Description of Procedure
Message in LCD
SERVICE MODE
(a)
NEXT CARE INFO
32 NEXT CARE
(b)
No.=< 1 ,2,3,4,5,6,7,8,9>
NEXT FC ROLL
(c)
018000P
NEXT BL UNIT
(d)
12000P
NEXT FU UNIT
(e)
100000P
NEXT TR DRUM
(f)
600000P
NEXT 240K KIT
(g)
240000P